TURBIDIMETERS

Click the product name to move to the target details.

DMT-52

FEATURES

Integrated structure with built-in turbidity sensor
The sensor replacement is easy and simple for maintenance
The long-life laser ensures a long continuous operation
Analog output is standardly equipped
Easy-to-see display with red digital LED

SPECIFICATIONS

MEASURING PRINCIPLE Light Scattering
MEASURING RANGE 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU
NOTE JTU stands for Japanese Turbidity Unit.
ANALOG OUTPUT 4 – 20 mADC
CONTACT OUTPUTS Error/Alarm (Upper limit)
SAMPLE FLOW RATE 100mL/min
POWER 100 VAC, 15 VA

DMT-5S&STA SENSOR

FEATURES

Separate type with the display unit separated from the sensor
The sensor replacement is easy and simple for maintenance
The long-life laser ensures a long continuous operation
Analog output is standardly equipped
Easy-to-see display with red digital LED

SPECIFICATIONS

MEASURING PRINCIPLE Light Scattering
MEASURING RANGE 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU
ANALOG OUTPUT 4 – 20 mADC
CONTACT OUTPUTS Error/Alarm (Upper limit)
SAMPLE FLOW RATE 100mL/min
POWER 100 VAC, 15 VA

DMT-400 SERIES

FEATURES

Up to 4 turbidity sensors can be connected
The sensor replacement is easy and simple for maintenance
The long-life laser ensures a long continuous operation
Up to 4 analog outputs are standardly equipped
Easy-to-read display of vacuum fluorescent tube

SPECIFICATIONS

MEASURING PRINCIPLE Light Scattering
MEASURING RANGE 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU
SENSORS Up to 4 sensors can be connected
OUTPUTS 1 – 4 analog outputs
CONTACT OUTPUTS Contact outputs for errors/alarms
SAMPLE FLOW RATE 100mL/min
POWER 24 VDC, 1 A

DMT-200&DMT-111、DMT-121、DMT-131

FEATURES

Separate type with the display unit separated from the sensor
1 or 2 sensors can be connected to the display unit.
The long-life laser ensures a long continuous operation
1 or 2 analog outputs
Easy-to-read display of vacuum fluorescent tube

SPECIFICATIONS

MEASURING PRINCIPLE Light Scattering
MEASURING RANGE 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU
SENSORS 1 or 2 sensors can be connected
OUTPUTS 1 or 2 analog outputs
  Contact outputs for errors/alarms
SAMPLE FLOW RATE 100mL/min
POWER 100 VAC, 15 VA

DMT-110、DMT-120、DMT-130

FEATURES

The compact design enables you to have a wide choice of mounting place.
The sensor itself works as a turbidimeter with built-in LED display.
The standard digital output(RS485) allows you to connect to a computer or a PLC.
The long-life laser ensures a long continuous operation
The optional analog output is available.

SPECIFICATIONS

MEASURING PRINCIPLE Light Scattering
MEASURING RANGE 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU
DIGITAL OUTPUT 1 RS485 (Can be converted to USB)
ANALOG OUTPUT Optional
SAMPLE FLOW RATE 100mL/min
POWER 24 VDC, 1 A

DMT-800、DMW-800

FEATURES

A pump, a printer and a flowmeter are integrated for easy-to-use operation.
A battery can be optionally equipped for portable operation where no power is available.
The optional software allows you to connect it to the computer.
The long-life laser ensures a long continuous operation
Up to 4 channels can be measured (DMW – 800)
A particle sensor can be additionally equipped. (DMW – 800)

SPECIFICATIONS

MEASURING PRINCIPLE Light Scattering
MEASURING RANGE 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU
ANALOG OUTPUT Optional
SAMPLE FLOW RATE 50 or 100 mL/min
POWER with AC adaptor

DMT-242A

FEATURES

Easy to install with the integrated structure of sensor with bubble removing chamber
Easy to calibrate on site
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube

SPECIFICATIONS

MEASURING PRINCIPLE 90-Degree Lateral Light Scattering
MEASURING RANGE 0.000 – 100.0 JTU
ANALOG OUTPUT 4 – 20 mADC
CONTACT OUTPUTS Error/Alarm (Upper limit)
SAMPLE FLOW RATE 250 – 750 mL/min
POWER 100 VAC, 50 VA

DMT-243A

FEATURES

Easy to install with the integrated structure of sensor with bubble removing chamber
Easy to calibrate on site
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube

SPECIFICATIONS

MEASURING PRINCIPLE 90-Degree Lateral Light Scattering
MEASURING RANGE 0.00 – 500.0 JTU
ANALOG OUTPUT 4 – 20 mADC
CONTACT OUTPUTS Error/Alarm (Upper limit)
SAMPLE FLOW RATE 250-750mL/min
POWER 100 VAC, 50 VA

DMT-244A

FEATURES

Easy to install with the integrated structure of sensor with bubble removing chamber
Easy to calibrate on site
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube

SPECIFICATIONS

MEASURING PRINCIPLE Surface Light Scattering
MEASURING RANGE 0.00 – 500.0 JTU
ANALOG OUTPUT 4 – 20 mADC
CONTACT OUTPUTS Error/Alarm (Upper limit)
SAMPLE FLOW RATE 250-750mL/min
POWER 100 VAC, 50 VA

DMT-200&TC100orTC500orTC3000

FEATURES

Easy to install with the immersible sensors
Automatic cleaning of the measurement windows section with the wiper
The sensor body is made of 316L SS with high durability
The measurement windows are made of scratch-resistant artificial sapphire glass
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube

SPECIFICATIONS

MEASURING PRINCIPLE Light Transmitting
MEASURING RANGE 0.0 – 100, 0 – 500, 0 – 3000 JTU (Depending on the sensor)
ANALOG OUTPUT 4 – 20 mADC
CONTACT OUTPUTS Error/Alarm (Upper limit)
POWER 100 VAC, 30 VA