DMT-52

FEATURES
Integrated structure with built-in turbidity sensor
The sensor replacement is easy and simple for maintenance
The long-life laser ensures a long continuous operation
Analog output is standardly equipped
Easy-to-see display with red digital LED
SPECIFICATIONS
MEASURING PRINCIPLE | Light Scattering |
---|---|
MEASURING RANGE | 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU |
NOTE | JTU stands for Japanese Turbidity Unit. |
ANALOG OUTPUT | 4 – 20 mADC |
CONTACT OUTPUTS | Error/Alarm (Upper limit) |
SAMPLE FLOW RATE | 100mL/min |
POWER | 100 VAC, 15 VA |
DMT-5S&STA SENSOR

FEATURES
Separate type with the display unit separated from the sensor
The sensor replacement is easy and simple for maintenance
The long-life laser ensures a long continuous operation
Analog output is standardly equipped
Easy-to-see display with red digital LED
SPECIFICATIONS
MEASURING PRINCIPLE | Light Scattering |
---|---|
MEASURING RANGE | 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU |
ANALOG OUTPUT | 4 – 20 mADC |
CONTACT OUTPUTS | Error/Alarm (Upper limit) |
SAMPLE FLOW RATE | 100mL/min |
POWER | 100 VAC, 15 VA |
DMT-400 SERIES

FEATURES
Up to 4 turbidity sensors can be connected
The sensor replacement is easy and simple for maintenance
The long-life laser ensures a long continuous operation
Up to 4 analog outputs are standardly equipped
Easy-to-read display of vacuum fluorescent tube
SPECIFICATIONS
MEASURING PRINCIPLE | Light Scattering |
---|---|
MEASURING RANGE | 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU |
SENSORS | Up to 4 sensors can be connected |
OUTPUTS | 1 – 4 analog outputs |
CONTACT OUTPUTS | Contact outputs for errors/alarms |
SAMPLE FLOW RATE | 100mL/min |
POWER | 24 VDC, 1 A |
DMT-200&DMT-111、DMT-121、DMT-131

FEATURES
Separate type with the display unit separated from the sensor
1 or 2 sensors can be connected to the display unit.
The long-life laser ensures a long continuous operation
1 or 2 analog outputs
Easy-to-read display of vacuum fluorescent tube
SPECIFICATIONS
MEASURING PRINCIPLE | Light Scattering |
---|---|
MEASURING RANGE | 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU |
SENSORS | 1 or 2 sensors can be connected |
OUTPUTS | 1 or 2 analog outputs |
Contact outputs for errors/alarms | |
SAMPLE FLOW RATE | 100mL/min |
POWER | 100 VAC, 15 VA |
DMT-110、DMT-120、DMT-130

FEATURES
The compact design enables you to have a wide choice of mounting place.
The sensor itself works as a turbidimeter with built-in LED display.
The standard digital output(RS485) allows you to connect to a computer or a PLC.
The long-life laser ensures a long continuous operation
The optional analog output is available.
SPECIFICATIONS
MEASURING PRINCIPLE | Light Scattering |
---|---|
MEASURING RANGE | 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU |
DIGITAL OUTPUT | 1 RS485 (Can be converted to USB) |
ANALOG OUTPUT | Optional |
SAMPLE FLOW RATE | 100mL/min |
POWER | 24 VDC, 1 A |
DMT-800、DMW-800

FEATURES
A pump, a printer and a flowmeter are integrated for easy-to-use operation.
A battery can be optionally equipped for portable operation where no power is available.
The optional software allows you to connect it to the computer.
The long-life laser ensures a long continuous operation
Up to 4 channels can be measured (DMW – 800)
A particle sensor can be additionally equipped. (DMW – 800)
SPECIFICATIONS
MEASURING PRINCIPLE | Light Scattering |
---|---|
MEASURING RANGE | 0.0000 – 2.0000 JTU OR 0.000 – 20.000 JTU |
ANALOG OUTPUT | Optional |
SAMPLE FLOW RATE | 50 or 100 mL/min |
POWER | with AC adaptor |
DMT-242A

FEATURES
Easy to install with the integrated structure of sensor with bubble removing chamber
Easy to calibrate on site
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube
SPECIFICATIONS
MEASURING PRINCIPLE | 90-Degree Lateral Light Scattering |
---|---|
MEASURING RANGE | 0.000 – 100.0 JTU |
ANALOG OUTPUT | 4 – 20 mADC |
CONTACT OUTPUTS | Error/Alarm (Upper limit) |
SAMPLE FLOW RATE | 250 – 750 mL/min |
POWER | 100 VAC, 50 VA |
DMT-243A

FEATURES
Easy to install with the integrated structure of sensor with bubble removing chamber
Easy to calibrate on site
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube
SPECIFICATIONS
MEASURING PRINCIPLE | 90-Degree Lateral Light Scattering |
---|---|
MEASURING RANGE | 0.00 – 500.0 JTU |
ANALOG OUTPUT | 4 – 20 mADC |
CONTACT OUTPUTS | Error/Alarm (Upper limit) |
SAMPLE FLOW RATE | 250-750mL/min |
POWER | 100 VAC, 50 VA |
DMT-244A

FEATURES
Easy to install with the integrated structure of sensor with bubble removing chamber
Easy to calibrate on site
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube
SPECIFICATIONS
MEASURING PRINCIPLE | Surface Light Scattering |
---|---|
MEASURING RANGE | 0.00 – 500.0 JTU |
ANALOG OUTPUT | 4 – 20 mADC |
CONTACT OUTPUTS | Error/Alarm (Upper limit) |
SAMPLE FLOW RATE | 250-750mL/min |
POWER | 100 VAC, 50 VA |
DMT-200&TC100orTC500orTC3000

FEATURES
Easy to install with the immersible sensors
Automatic cleaning of the measurement windows section with the wiper
The sensor body is made of 316L SS with high durability
The measurement windows are made of scratch-resistant artificial sapphire glass
Adopting LEDs as light source to achieve long life
Analog output is standardly equipped
Easy-to-read display of vacuum fluorescent tube
SPECIFICATIONS
MEASURING PRINCIPLE | Light Transmitting |
---|---|
MEASURING RANGE | 0.0 – 100, 0 – 500, 0 – 3000 JTU (Depending on the sensor) |
ANALOG OUTPUT | 4 – 20 mADC |
CONTACT OUTPUTS | Error/Alarm (Upper limit) |
POWER | 100 VAC, 30 VA |